MID0106 Last PowerMACS tightening result event
variables
The event variables available to an Atlas Copco Event
Message, MID0106 event trigger
are:
Event Variable Name | Description |
---|---|
Device Name | The name of the deviceWISE Device that received this message |
Bolt A | The Angle value for each bolt in the tightening result |
Bolt A High Limit | The Angle High Limit value for each bolt in the tightening result |
Bolt A Low Limit | The Angle Low Limit value for each bolt in the tightening result |
Bolt Angle Status | The status of the Angle value for each bolt in the tightening result |
Bolt Count | The number of bolts reported in this tightening result |
Bolt Number | The ordinal bolt number assigned to each bolt |
Bolt T | The Torque value for each bolt in the tightening result |
Bolt T High Limit | The Torque High Limit value for each bolt in the tightening result |
Bolt T Low Limit | The Torque Low Limit value for each bolt in the tightening result |
Bolt Torque Status | The status of the Torque value for each bolt in the tightening result |
Data No System | A unique ID for each tightening result within the system |
Message Number | This number is always 1 as it is the first message in the tightening result |
Mode Name | The name of the Mode used for the tightening |
Mode Number | The mode number used in the tightening. This will be a value between 1 and 50. |
PM Status |
The status of the tightening.
|
Simple Status |
Simplified status of the tightening.
|
Special Variable Count | Count of the number of Special values specified in the message |
Special Variable Names | An array of the names of the Special values in the message |
Special Variable Numeric Values | An array of numeric values that correspond with Integer ("I") or Floating Point ("F") Special Variable Type items. |
Special Variable String Values | An array of string values that correspond with String ("S") Special Variable Type items. |
Special Variable Types | An array of string values that indicate the data type of the Special Variable Value. |
Station Name | The name of the station reporting the tightening data |
Station Number | The number that identifies the station reporting the tightening data. The range of values is 1 - 15. |
Time | The cycle start time for each tightening sent to the control station. |
Total Number of Messages | The total number of messages needed to send all Bolt data for all bolts. |
Wp ID | The Work Process ID associated with the tightening. |