MID0106 Last PowerMACS tightening result event variables

The event variables available to an Atlas Copco Event Message, MID0106 event trigger are:

Event Variable Name Description
Device Name The name of the deviceWISE Device that received this message
Bolt A The Angle value for each bolt in the tightening result
Bolt A High Limit The Angle High Limit value for each bolt in the tightening result
Bolt A Low Limit The Angle Low Limit value for each bolt in the tightening result
Bolt Angle Status The status of the Angle value for each bolt in the tightening result
Bolt Count The number of bolts reported in this tightening result
Bolt Number The ordinal bolt number assigned to each bolt
Bolt T The Torque value for each bolt in the tightening result
Bolt T High Limit The Torque High Limit value for each bolt in the tightening result
Bolt T Low Limit The Torque Low Limit value for each bolt in the tightening result
Bolt Torque Status The status of the Torque value for each bolt in the tightening result
Data No System A unique ID for each tightening result within the system
Message Number This number is always 1 as it is the first message in the tightening result
Mode Name The name of the Mode used for the tightening
Mode Number The mode number used in the tightening. This will be a value between 1 and 50.
PM Status

The status of the tightening.

  • 0 - OK

  • 1 - OKR

  • 2 - NOK

  • 3 - TERMINOK

Simple Status

Simplified status of the tightening.

  • 0 - NOK

  • 1 - OK

Special Variable Count Count of the number of Special values specified in the message
Special Variable Names An array of the names of the Special values in the message
Special Variable Numeric Values An array of numeric values that correspond with Integer ("I") or Floating Point ("F") Special Variable Type items.
Special Variable String Values An array of string values that correspond with String ("S") Special Variable Type items.
Special Variable Types An array of string values that indicate the data type of the Special Variable Value.
Station Name The name of the station reporting the tightening data
Station Number The number that identifies the station reporting the tightening data. The range of values is 1 - 15.
Time The cycle start time for each tightening sent to the control station.
Total Number of Messages The total number of messages needed to send all Bolt data for all bolts.
Wp ID The Work Process ID associated with the tightening.