MID1201 Operation Result Overall Data
The event variables available to an Atlas Copco Event
Message, MID1201 Operation Result Overall Data event trigger
are:
Event Variable Name | Description |
---|---|
Device Name | The name of the device that received the message. |
IP Address | The IP Address of the Atlas Copco Power Focus 6000 Flex that generated the message. |
Message Number | This value will always be 1 and represents the sequential order of the MID1201 and MID1202 messages that will be sent from the controller for this Operation |
Total Number of Messages | This is the total number of MID1201 and MID1202 messages that will be sent from the controller for this Operation |
Operation Type |
The type of Operation that was performed. The following operation codes and their meaning are shown below.
|
Result Data Identifier | A unique ID for each operation result within the controller. This will match the Result Data Identifier in subsequent MID1202 Operation Result Object Data messages |
Result Status | The total status of the operation. One byte long and is specified by one ASCII digit (‘0’ or ‘1’). 0=cycle NOK, 1=cycle OK |
Time | Cyple start time for each operation sent to the control station. |
Data Field Count | The number of variable data fields that are in the message. This value will determine the number of valid entries in the following Data Field data arrays to follow. A value of 0 in this field indicates that there is no data field information and the Data Field data arrays can be ignored. |
Data Field - Data Types | The Data Type of the Data Field. A value of 4 or 7 indicates the value in ASCII characters and will be found in the "Data Field - Value As String" array. A value of 5 indicates the value is a TIMESTAMP value and will be found in the "Data Field - Value As Timestamp" array. All other values are numeric and will be represented as FLOAT4 data types. These values are found in the "Data Field - Value As Numeric" array. |
Data Field - Parameter IDs | The Parameter ID number for the Data Field. The parameter IDs that are common for all systems using open protocol. A full list of parameter ID values can be found in the Atlas Copco Open Protocol specification documentation. |
Data Field - Step Numbers | The Step Numbers for the Data Field. |
Data Field - Units | The Unit Types for the Data Field. The unit types are common for all systems using open protocol. A full list of unit type values can be found in the Atlas Copco Open Protocol specification documentation. |
Data Field - Value As String | The value of the Data Field for Data Fields that have a Data Types value of either 4 or 7. |
Data Field - Value As Timestamp | The value of the Data Field for Data Fields that have a Data Types value of 5. |
Data Field - Values As Number | The value of the Data Field for all other Data Field Data Types values. |
Object Data Count | The total number of objects in the operation. This value will determine the number of valid entries in the following Object Data data arrays to follow. A value of 0 in this field indicates that there is no object data information and the Object Data data arrays can be ignored |
Message Revision Number | A value between 1 and 3 that indicates the Revision Level of the MID1201 message. The Object Data -Types and Object Data - Reference IDs data arrays are only supported for Revision Level 3. These two data arrays can be ignored if the Message Revision Number has a value of either 1 or 2. |
Object Data - IDs | The user defined Object ID for this Object Data element |
Object Data - Status | The status of the operation object. 0 = NOK, 1 = OK |
Object Data - Types |
The type of the operation object.
|
Object Data - Referenced IDs | Link to related Object ID. |