Job Batch Decrement

The Job Batch Decrement action decrements the job batch for a current running job. This is performed by sending a MID0129.

Parameters

Parameter Description
Device Input Type The method to supply the device name to the action. The options are:
  • Static - select the device name from the Device Name parameter
  • Dynamic - enter the device name in the Device Name input variable. This allows the device name to be passed to the action during trigger execution.
Device Name Select Estic.

Displayed when the Static option is selected in the Device Input Type parameter.

Revision Select either Rev 1(Last Tightening) or Rev 2 (Cell Job).
The default value is Rev 1 and always decrements the last tightening completed in a job.
If the Rev 2 option is selected, two additional parameters, the Channel ID and the PSET ID become available on the Input tab.

Input tab

Parameter Description
Device Name Displayed when the Dynamic option is selected in the Device Input Type parameter.

This variable will hold the name of the device where job batch decrement will be performed.

Channel ID The channel ID to be decremented. In case of a cell job each controller member has a unique channel ID.
This parameter is available when the Rev 2(Cell Job) Revision parameter is selected.
PSET ID The parameter set ID to be decremented in the job.
This parameter is available when the Rev 2(Cell Job) Revision parameter is selected.