IFM IO-Link Master Process Data Output
When it comes to writing to IO-Link devices, the IFM IO-Link IoT Master driver only supports a few sensors out of the box. In order to test an output device, not only does the IODD file need to exist, but the device id must be placed in the Sensor List field on the device configuration. The Sensor List field appears when the Use Advanced Properties option is checked. The Sensor List is a comma delimited field of device ids that the driver will recognize and make available in the Sensor Control action.
The default sensor that are supported out of the box are:
Device ID | Description |
---|---|
863 | SD6501 - Compressed air meter |
949 | SM6120/6020 - Magnetic-inductive flow meter |
1085 | DV2130 - LED-Lamp/IOL/Buzzer |
1176 | DV2131 - LED-Lamp/IOL/Buzzer/Button |
1367 | VVB001 Status B - Vibration sensor |