Defining Reads

The Reads tab is used to configure LWM2M Reads.

Enter/Select the following fields to configure the Reads setting:

Field Description
Object Select the Object you want to read.
Instance Select the Instance you want to read.
Resource Select the Resource you want to read.
Read on register Select Yes, if you want to read the values when the device registers and No, if you do not want to read the values when the device registers.
Read on update Select Yes, if you want to read the values when there is an update No, if you do not want to read during the updates.
Observe Select Yes, if you want to observe the values and No, if you do not want to observe the value changes.
Set PMIN/PMAX attributes on observe Observe the set PMIN/PMAX of the selected object.

PMIN - Min. time in second between sending notifications for a resource if any of the notify conditions are met

PMAX - Max. time in seconds between sending successive notifications for a resource if none of other notify conditions are satisfied

Priority Set to true if this path should be executed before others.