Time Management
The Time Management tab is used to set
the node's time and time zone, and configure time
synchronization parameters.
This tab is not available on all products. For products
that rely on the underlying operating system tools for time
management functions (for example, Enterprise Gateway
products), the time management tasks are performed using
the operating system tools.
The Enterprise Gateway for Siemens ERPC product only
provides the function to set the node's time zone. Other
time management functions tasks are accomplished using the
Siemens configuration tools.
In addition to the Time Management function to synchronize time with a time server, nodes can synchronize their time with the Management Portal. For more information, see TR50 Advanced Connection Management tab.
Set Time
The Set Time section has display fields, parameters and buttons as follows:
Parameter | Description |
---|---|
Device Time | The node's local time, taking into
account the node's time zone.
A restart of deviceWISE is required in order for the updated Time Zone setting to take effect. For more information on restarting deviceWISE, see Restart section in Node Administration. |
Local Time | The Workbench computer's time, taking into account the computer's time zone. |
Set Time | Select to set the node's time to the Workbench's time, relative to GMT (taking into account the time zones of the two computers). |
Device Time Zone | Displays the node's current time zone. Select a time zone from the list of supported time zones to set using the Set Device Time Zone button. |
Set Device Time Zone | Select to set the node's tome zone to the current selection from the Device Time Zone selection list. |
Time Synchronization Settings
The Time Synchronization Settings section has display fields, parameters and buttons as follows:
Parameter | Description |
---|---|
Scheduled Synchronization | A checkbox that enables the time
synchronization feature for the node.
If the checkbox is not selected, the
other parameters are maintained, but
the time synchronization feature is
disabled. When the checkbox is selected, the other parameters become available for configuring. |
Frequency | The frequency of that the node will
request a time synchronization with the
time server(s). When a selection is
made, other parameters become
available. The options are:
|
Primary Time Server | The IP address of the primary time server. The time server may be a local network time server or an internet time server that accepts client time requests according to the selected Protocol parameter. |
Port | The port to use for the client time requests, normally port 123. |
Protocol | The time synchronization protocol to
use. The options are:
|
Secondary Time Server | The secondary IP address to use if the Primary Time Server can not be reached. |
Port | The port to use for the Secondary Time Server, normally port 123. |
Protocol | The time synchronization protocol to
use for the Secondary Time
Serve. The options are:
|
Save Synchronization Settings | Select after changing the time synchronization settings parameters to have the changes saved. |
Synchronize Now | Select to have a time synchronization request take place immediately. |