IoT Gateway 19.1.12 Release Notes
What's new in the IoT Gateway 19.1.12 release
The latest released build is 19.1.12-002.
Customers upgrading the Asset Gateway for the CalAmp RevG products should use 19.1.11 or wait for a later release.

Customer Documentation Reminder
- Customer documentation updates after December 1, 2018 are hosted on https://docs.devicewise.com .
- The old customer documentation site, https://help.devicewise.com, points to the new customer documentation site’s home page.
deviceWISE Runtime
- MQTT Publish Receive Event and the MQTT Publish action to allow the dynamic reference of an MQTT device. Plus allow setting of Retain flag.
- Fix defects.
OPC UA Server (Prototype update)
- Add support for structure UDT arrays for Rockwell and other PLCs
- Support multi-dimensional arrays for Omron, Rockwell and other PLCs
Workbench
- Bug fixes
Drivers
Navigate to the Management Portal -> Developer page -> Resources item to identify the drivers and driver versions supported on a specific platform with this release. Both new installations and updates should include the drivers for this release.
- Atlas Copco – Reduce logging
- AcraDyne, Estic, Stanley – Enable dynamic device reference in actions
- OPC UA Client – Increase timeout value to connect to server
- OPC UA Server – Bug fixes and support for UDT and multi-dimensional arrays
- BACNet – Fix crash that occurs during shutdown
- Siemens – Fix start issues associated with the S5 PLC

The following defects were fixed in this release.
deviceWISE Runtime
MAP-14606: Unable to export certain projects and triggers
Description: We now detect a circular reference when doing an export. We only export a trigger once when the circular reference is detected. Fixed in 19.1.12.
MAP-14593: Windows GUID implementation is generating duplicate GUIDs
Description: Fixed in 19.1.12.
MAP-14579: Purging reports affects logging to the exception log
Description: Moving report table to a different database. See MAP-14351. Fixed in 19.1.12.
MAP-14566: Document the TR50 error codes
Description: Added missing error codes in 19.1.12.
MAP-14550: Azure action returns generic -7001 error if Azure is not connected
Description: Added new error codes in 19.1.12.
MAP-14539: Unable to export certain projects and triggers
Description: Fix infinite loop in exporting circular reference triggers in 19.1.12.
MAP-13988: Variable Block Write Crash
Description: Fixed in 19.1.12.
Drivers
MAP-14605: Internal Serial Driver doesn't work with COM ports > 9
Description: Simplify the code by checking the length of the string. Fixed in 19.1.12.
MAP-14572: Stanley, Estic, and AcraDyne actions fail with dynamic device names
Description: Add support for dynamic device names to these drivers in 19.1.12.
MAP-14570: Azure Extension: Freeing NULL pointer
Description: Removed unnecessary invocation of Azure’s init and deinit in 19.1.12.
MAP-14564: Siemens S5 device won't start
Description: Add updates to support Siemens S5 PLC in 19.1.12.
MAP-14477: Open Protocol Drivers - Excessive Logs on dw.driver.atlas.handler
Description: Change the log level so that these only display if user turns on enhanced system logging.
MAP-14453: The first two characters in Active VIN variable are wrong on Estic and IR INSIGHTqc
Description: Updated Estic and IR drivers with 19.1.12.
MAP-14139: Node caught is endless crash when BACNet device is stopped
Description: Fixed in 19.1.12.
Workbench
MAP-14563: "Set Thing Attr" is not returning any value
Description: Fixed in 19.1.12.

More information about drivers can be found on the Device driver list.
The following drivers are fully supported and deemed "Generally Available" with this release.
Driver Name | Version |
---|---|
Atlas Copco – updated in 19.1.12 | 3.5.1 |
Beckhoff | 2.1.5 |
Apex Cleco – Updated in 19.1.12 | 1.8.1 |
Danlaw | 2.12.2 |
FANUC CNC | 1.2.2 |
FANUC | 2.3.1 |
NMEA GPS | 1.0.2 |
LDAP | 1.1.1 |
Lua | 1.1.2 |
Mitsubishi Electric | 3.3.3 |
MindSphere | 2.0.2 |
Modbus Client | 2.8.4 |
Modbus Server | 1.1.5 |
MQTT Client – Updated in 19.1.12 | 1.3.2 |
MTConnect | 1.2.6 |
OAuth2 | 2.3.0 |
Omron | 3.7.0 |
OPC DA Client | 2.6.0 |
OPC DA Server | 1.1.5 |
OPC UA Client – Updated in 19.1.12 | 2.4.5 |
Allen-Bradley (Rockwell Automation) | 2.17.8 |
Siemens – Updated in 19.1.12 | 2.10.4 |
Sysmon | 1.0.0 |
TR50 | 2.1.0 |
The following drivers have a "Pilot Ready" status.
Driver Name | Version |
---|---|
Pointer | 1.12.0 |
Emerson Rocplus | 2.0.2 |
SNMP | 1.0.0 |
Sturtevant Richmont – Updated in 19.1.12 | 1.8.1 |
TCP | 2.2.2 |
The following drivers and packages are "Prototype" level.
Driver Name | Version |
---|---|
AcraDyne – Updated in 19.1.12 | 1.0.1 |
Advanced Display Protocol | 1.0.1 |
Azure – Updated in 19.1.12 | 0.10.0 |
BACnet IP – Updated in 19.1.12 | 2.2.1 |
Banner Engineering | 1.0.0 |
Bosch Rexroth – Updated in 19.1.12 | 1.8.1 |
CTI | 2.1.4 |
Davis | 1.0.0 |
Escort Memory Systems (EMS) | 1.0.0 |
E-Sensors | 1.0.0 |
Estic – Updated in 19.1.12 | 1.0.1 |
Fuji | 1.0.0 |
GrovePi (Only in Raspbian directory) | 1.0.1 |
Hawkeye (MicroScan Systems) | 1.0.0 |
Hue | 1.0.0 |
iCaddy | 1.0.0 |
Ingersoll Rand – Updated in 19.1.12 | 1.2.1 |
Lora (Semtech) | 1.0.0 |
ScanTools OBD-II | 1.0.0 |
OPC UA Server – Updated in 19.1.12 | 1.0.3 |
Oramoc | 1.0.0 |
Pepperl+Fuchs | 1.0.1 |
Pike Aero | 1.0.0 |
Sandbox | 1.0.0 |
SICK CLV Scanner | 1.1.0 |
Sigfox | 1.0.0 |
SQElectronics | 1.0.0 |
Stanley – Updated in 19.1.12 | 1.0.1 |
Symbol | 1.0.2 |
Virtual | 1.3.0 |
WebMI | 2.0.0 |
WSAPI | 1.1.0 |
Xirgo | 1.3.0 |
Z-Wave | 1.0.0 |

deviceWISE Enterprise Gateway products
-
Software Products
- AIX 64-bit (Version 6.1 and Version 7.1 and Version 7.2)
- Linux 32-bit (CentOS 5 and CentOS 6)
-
Linux 64-bit (CentOS 6 and CentOS 7)
- No CentOS 5 support
- Full - for deviceWISE Enterprise Gateways for 32-bit Linux installed on 64-bit CentOS Operating Systems (requires 32-bit glibc, e.g. glibc.i686 on CentOS 7)
- Full - for deviceWISE Enterprise Gateway for 64-bit Linux
-
Windows (Windows XP SP3, Windows 7, Windows 10, and Windows Server 2008 R2, Windows Server 2012 R2, Windows Server 2016 64-bit)
- No support for Windows Home Edition
-
Embedded Products
- Dell Edge 5000 - WindRiver Linux 7; Ubuntu Server
- Mitsubishi MES Interface IT
- Mitsubishi WinCPU
- Rockwell ControlLogix
- Siemens ERPC
deviceWISE Asset Gateway products
-
Software Products
-
Linux 32-bit (CentOS 6)
- No CentOS 5 support
-
Linux 64-bit (CentOS 6 and CentOS 7)
- No CentOS 5 support
- Full - for deviceWISE Asset Gateways for 32-bit Linux installed on 64-bit CentOS Operating Systems (requires 32-bit glibc, e.g. glibc.i686 on CentOS 7)
- Full - for deviceWISE Asset Gateway for 64-bit Linux
- Linux 64-bit (Snap)
-
Windows (Windows 7, and Windows 10)
- No support for Windows Home Edition
-
Linux 32-bit (CentOS 6)
-
Embedded Products
- B+B SmartWorx Spectre V3
- CalAmp LMU-5000 (Rev C and Rev G)
- CalAmp CDM-5030
- Cisco 829
- Cisco IE 4000
- Cypress CTM-200
- Dell Edge 5000 - WindRiver Linux 7
- GateTel EZMoto V2
- Mitsubishi CCPU
- MultiTech Conduit (with Serial and GPIO and cellular modules)
- MultiTech Conduit AEP for AT&T**
- MultiTech OCG-D (Models H5)
- MultiTech rCell (Model MTR-LAT1-B07)
- Option CloudGate (Models CG0192 and CG0112 with v1.x or v2.x firmware)
- RedLion (Pilot Ready)
- Siemens (MicroBox, NanoBox)*
- Siemens IoT 2000 (Wired only)
- Siemens ERPC*
- Systech SysLINK SL-500
- USRobotics 3510
- Vantron VT-M2M-LV
- Xmodus XM1710E (Pilot Ready)
Limited Release** features
*
- Denotes a supported gateway that was not specifically tested for this
release. Of the Asset Gateways listed, most use a standard Linux or
Windows load or they are very similar to a tested Enterprise Gateway.
**
- Limited Release features meet customer specific features and
configurations. These features may not be available in all hardware and
operating system configurations.

Actions and Events
MAP-7740: Log Message action not logging the $ char in a log message
Description: The Log Message action does not write the $ char in an exception log message. This can be bypassed by using 2 $ chars back to back.
Hot-Edit of Started Triggers
MAP-11421: deviceWISE crashed when Editing and Saving a Started trigger
Description: Intermittent issue where deviceWISE crashed when attempting to Edit and Save a Started and Loaded trigger
Asset Gateway for CalAmp
MAP-5369: OS Shutdown action does not work on a CalAmp RevC or RevG
Description: The OS Shutdown action does nothing when executed on a CalAmp RevC or RevG. This feature has not been implemented in the Asset Gateway for CalAmp.
MAP-14633: Segfault crash on CalAmp RevG when doing a Local DB Select action
Description: When executing a trigger with the Local DB Select action on a CalAmp RevG, the node will crash with a segfault. The crash seems to only occur when the Return Result as Array parameter is set to True. No other platforms (including CalAmp RevC and CalAmp CDM-5030) exhibited this behavior.
Asset Gateway for MultiTech
MAP-4860: Local time zone for Brussels is 2-hours off
Description: Setting the local time for Brussels, Belgium is two hours off in the Asset Gateway for MultiTech.
Workaround: Select the local time option for Paris, France in the Asset Gateway for MultiTech.
MAP-12085: MultiTech OCG platform Local I/O initialization failure
Description: Local I/O features do not work in releases from 17.1.13 through 17.2.8. This was fixed in 17.2.9.
Asset Gateway for Option CloudGate
MAP-8230: Option V2 CDMA: Message corruption on Send SMS
Description: For Option CloudGate CDMA-equipped models, cellular Actions and Events related to SMS send and receive are not supported.
MAP-8231: Option V2 CDMA: Sending a large SMS message fails on with internal CloudGate api error
Description: For CloudGate Option CDMA-equipped models, cellular Actions and Events related to SMS send and receive are not supported. Sending a large SMS > 160 characters fails with a CloudGate API error on an option V2 CDMA node.
MAP-10092: No TR50 S&F disk storage type support for Option CloudGate V1
Description: TR50 S&F support is present, but the S&F disk storage type is not available.
Asset Gateway for USRobotics
MAP-10662: No TR50 S&F disk storage type support for USRobotics
Description: TR50 S&F support is present, but the S&F disk storage type is not available.
Device types
MAP-9212: Be aware of endianness when importing or exporting Global Variables device and data values
Description: When exporting a Global Variables device with its data values from one node and then importing the Global Variables device and the data values into another node, the endianness of the nodes must be taken into consideration. For example: exporting from a big endian node (Power PC) and then importing into a little endian node (X86). The numeric data values will not be correctly represented in the imported node.
After the import, the Global Variables device should be edited, and the data values reviewed and modified.
Enterprise Gateway for Siemens ERPC
MAP-1933: On a Enterprise Gateway for Siemens ERPC, a controlled Listener fails to connect to queue manager on first attempt
Description: When accessing a WebSphere MQ server via a transport or a listener, the very first connect request after boot fails due to a limitation in the firmware. Subsequent connect requests work correctly.
Workaround: Repeat the connect request.
MAP-3634: FTP action with Transfer Mode set to Active fails on Enterprise Gateway for Siemens ERPC
Description: When using a trigger FTP action, the Put and Get operations do not work when Transfer Mode set to Active on ERPC.
Workaround: Set the Transfer Mode parameter to Passive instead of Active until the problem is fixed in a future release.
MAP-5707: FTP client does not connect to server in passive mode on ERPC
Description: The deviceWISE FTP Server in the Enterprise Gateway for Siemens ERPC cannot support a FTP client in passive mode.
Workaround: Use the FTP active mode instead.
MAP-6793: A TR50 connection with SSL will fail on ERPC
Description: TR-50 is not supported on the ERPC platform
MAP-9820: VxWorks-based Enterprise gateway platforms lose SQLServer Connectivity after Windows updates
Description: Windows updates add new items to the Windows cipher suite and change the default order of items within the cipher suite. This prevents a successful connection with SQL server.
Workaround: Move this cipher suite “TLS_RSA_WITH_AES_256_CBC_SHA (53)”, to the top of the list of cipher suites. See the More Information section on this Microsoft page for instructions to configure the SSL Cipher Suite Order Group Policy setting : https://support.microsoft.com/en-us/kb/3161639. Using this method retains the order of the cipher suites across subsequent Windows updates.
MAP-11664: VxWorks-based Enterprise gateway platforms cannot process empty ResultSets from an Oracle Stored procedure
Description: If you execute an Oracle database stored procedure transport map that returns result sets in output parameters the transaction action will fail if the result set output parameter is null.
MAP-11665: VxWorks-based Enterprise gateway platforms cannot process empty ResultSets from a SQLServer Stored procedure
Description: If you execute an SQLServer database stored procedure transport map that returns result sets the transaction action will fail if the result set is empty.
Enterprise Gateway for Windows
MAP-3455: The Enterprise Gateway for Windows Restart feature from the Node Administration tab does not work as designed
Description: The Restart feature available from Workbench -> Administration -> Node Administration tab may not cleanly stop and then restart the runtime. When there are many active transports and listeners, the Transaction Server does not restart properly.
Workaround: Follow the instructions in the section "Manually restarting a node" on Enabling MySQL support.
MAP-10766: Logon credentials for the Windows Services "deviceWISE Transaction Engine" and "deviceWISE Core" are reset after deviceWISE upgrade or downgrade
Description: If you change the logon credentials of the deviceWISE Windows Service entries which include "deviceWISE Transaction Engine" and "deviceWISE Core", they will be reset to the default service credentials after a firmware update to a newer or older version.
Workaround: Navigate to the services panel and re-enter the logon credentials after the firmware update and restart the service entries.
This is addressed in version 18.2.4 or later.
Local Database (Local DB)
MAP-4732: The Local DB Import action with the "First Row is Header" parameter set to true fails.
Description: Importing a csv file with a header row into a Local DB table will cause a failure.
Workaround: Set the "First Row is Header" parameter to false, import it, and then remove the first row.
MAP-5404: Problem reading database entries when a comma/line-feed combination is the last item in a list of database entries
Description: If a comma/line-feed combination is the last item in a list of database entries, then a problem occurs
Workaround: Add a dummy column in the database to represent the blank after the comma. For example, if you have 15 data entries and the last entry has a comma, then add a 16th column to your database.
Modem
MAP-3167: Simultaneous Cellular connect/disconnect and Modem power on/off can cause reboot of Asset Gateway
Description: We found a scenario where the Asset Gateway will reboot when simultaneous control actions are executed. When the Set Modem Power Level action and the Control Cellular Connection action (or Workbench operation) is executed repeatedly and simultaneously, a crash can occur resulting in a reboot.
We have not seen this problem during normal operation where the use of the Set Modem Power Level action cycling of power between "Online" and "Low Power" rarely occurs.
Transaction Server
MAP-685: Transports do not recover properly from Store and Forward
Description: When using the WMQ transport and the transport reports the error MQJMS007, it might cause the transport to switch in and out of Store and Forward, even though the transactions are successfully delivered to the WMQ queue.
Workaround: Check the WMQ queue manager. If the listener shows the state other than Started, then it is likely that you have encountered this issue. Set the listener to Started to restore proper functionality.
MAP-2972: Enterprise Gateway for Siemens ERPC faults with Transaction Server not being able to connect after a package remove
Description: After an Add or Remove of a package, such as a device driver, the node might have a fault where the Transaction Server cannot connect.
Workaround: You will need to restart deviceWISE. Follow the instructions for Manually restarting a deviceWISE node on Packages.
MAP-3930: IFS: sometimes the Transaction Server fails to start
Description: When setting transports, especially an iTAC transport, with "Load transport at initialization" parameter checked, and using a memory optimized Transaction Server that is not a match for the transports with "Load transport at initialization", it is possible that the Transaction Server will fail to start on Mitsubishi MESInterface IT nodes. Rebooting the module with the "Standard" Enterprise Access option will allow the Transaction Server to come up successfully, the transports can then be modified to remove the "Load transport at initialization" parameter. The memory optimized Transaction Server can then be re-set to the desired one.
MAP-4002: Updating logical variables in a transport map and not editing the corresponding trigger can lead to undesirable consequences.
Description: In this scenario the trigger will be disabled when it fires, and the action will return an error code of -6409 (invalid variable type) in the Exceptions log. Because the trigger will not be recovered on its own, the user will have to edit and re-save the trigger manually.
MAP-4796: NVARCHAR Support Limitation
Description: The NVARCHAR and NCHAR datatypes for Oracle are not supported on the following platforms:
- Mitsubishi MESInterface-IT
- deviceWISE Enterprise Gateway for Siemens ERPC
MAP-5170: JSON payload transport maps for the HTTP transport are not supported on all platforms
Description: This feature is not supported on the following platforms:
- Mitsubishi MESInterface-IT
- deviceWISE Enterprise Gateway for Siemens ERPC
MAP-5684: JMS Netweaver Transport/Listener on an Enterprise Gateway for Siemens ERPC cannot initialize connection with the JMS Netweaver server
Description: This feature is not supported on the following platforms:
- Mitsubishi MESInterface-IT
- deviceWISE Enterprise Gateway for Siemens ERPC
MAP-5685: JMS Netweaver support jars are not packaged with the ERPC or MESInterface IT product install files
Description: This feature is not supported on the following platforms:
- Mitsubishi MESInterface-IT
- deviceWISE Enterprise Gateway for Siemens ERPC
MAP-6604: HANA database insert fails ERPC
Description: The NVARCHAR and NCHAR datatypes are not supported on the deviceWISE Enterprise Gateway for Siemens ERPC product.
MAP-7388: New Oracle JDBC driver transport maps cannot enumerate schemas/table definitions on an Oracle 9 server
Description: Beginning with the deviceWISE 15.1 release, the deviceWISE Enterprise Gateway products for Linux, Windows and AIX use a later version of the Oracle JDBC driver that only supports Oracle 12.1, 11.2, 11.1.
Oracle 9.2 was end-of-lifed in July 2010.
- The FAQ link is here: http://www.oracle.com/technetwork/database/enterprise-edition/jdbc-faq-090281.html#01_02
- The end-of-life information for Oracle database server products is here: http://www.oracle.com/us/support/library/lifetime-support-technology-069183.pdf
The MESInterface-IT and deviceWISE Enterprise Gateway for Siemens ERPC products are able to enumerate schemas from Oracle 9.2 because the JDBC driver has not been updated.
MAP-9082: Null Macro test: Select fails when a default timestamp of format 01/11/12 12:45:00.000 is used in place of a NULL value returned
Description: If you need to specify a default value for SQLServer datatypes for DATE and TIME when using the following enterprise gateway products:
- Mitsubishi MESInterface-IT
- Enterprise Gateway for Siemens ERPC
then you will need to use a long value that represents milliseconds since 1/1/1970 instead of the default format 'mm/dd/yy HH:MM:SS.sss',
MAP-11311: AIX java8: SSL Error when attempting to connect to SQL Server 2008 and below
Description: The database transport on deviceWISE Enterprise Gateway for AIX and AIX64 cannot complete a connection to SQLServer 2008 running on Windows XP due to incompatibility with SSL. The workaround is to access the SQLServer database on a newer operating system.
MAP-12324: VxWorks platforms: Failure to connect to Oracle 12c server with SQLException: No matching authentication protocol
Description:
VxWorks-based platforms with Oracle database transport fails to connect
to the Oracle 12c server with the following error:
"java.sql.SQLException: ORA-28040: No matching authentication protocol "
The
issue is caused because Oracle 12c is configured to use a default
minimum authentication protocol of 11 and the VxWorks-based gateway
product uses an older unsupported JDBC driver tied to JDK 1.5. This is
equivalent to an Oracle 8 client and consequently uses an Oracle 8
authentication protocol.
Workaround:
-
Configure the sqlnet.ora file with the following parameters to allow a version 8 authentication protocol.
- SQLNET.ALLOWED_LOGON_VERSION_SERVER=8
- SQLNET.ALLOWED_LOGON_VERSION_CLIENT=8
- SEC_CASE_SENSITIVE_LOGON=FALSE
- Restart the server for these changes to take effect.
-
If
you are planning on using an existing login id from the VxWorks runtime
you will need to use PL/SQL and alter the password of the user to force
the server to rehash passwords with compatible versions.
- A recommended approach would be to create a new login id and specify those credentials on the Oracle 12c Transport on the VxWorks runtime.
Reference links:
- https://docs.oracle.com/database/121/NETRF/sqlnet.htm#NETRF2016 (See the section on SQLNET.ALLOWED_LOGON_VERSION_SERVER. )
- https://developer.ibm.com/answers/questions/177075/after-upgrading-to-oracle-12c-database-i-start-get.html
- https://mikedietrichde.com/2017/04/24/having-some-fun-with-sec_case_sensitive_logon-and-ora-1017/.
MAP-12453: Accessing a HTTP or SOAP server that presents an untrusted server certificate
Description: Starting with Enterprise Gateway version 17.2.3, the HTTP and WS_SOAP transports have changed their behavior when establishing an HTTPS connection. The server needs to present a server certificate that is signed by a globally trusted CA. Otherwise the transport will receive a SSL Handshake Exception.
The workarounds are:
- Update the server certificate on the HTTPS server with one that is signed by a trusted CA.
- Create a java key store that includes the server's CA certificate using the keytool utility. Then specify this key store in the transport panel 'Keystore' and 'TrustStore' fields.
- A less preferred option is to add the Organization/Company's root CA certificate to the 'cacerts' file. Note that this file will be replaced when the enterprise gateway product is re-installed.
MAP-12885: MySQL Connector/J 8 version of the JDBC driver is incompatible with the Enterprise Gateway DB transport
Description: The mySQL Connector/J v8 JDBC driver has changed the package name of the class that implements the driver. Use the mySQL Connector v5.x JDBC driver instead to enable mySQL support in the enterprise gateway.
Transaction Server XSD support
MAP-3141: XSD: Xpath expression should not be saved in the XML if Specify Map and Sequence Keys in header check box is selected
Description: This issue only affects JMS listeners with the XSD payload. When there is both an XPath expression and a JMS header property specified on the JMS listener XSD Payload panel, and the header property is missing from the incoming JMS message, the XPath expression is used to determine the listener map id, instead of the default listener map id.
MAP-3695: XSD: Default or fixed value provided in the XSD will be erroneously used
Description: If the XSD used to create a listener map contains a required attribute with a default or fixed value, it is considered valid. At runtime, instead of the XML being rejected as invalid, the default or fixed value provided in the XSD will be erroneously used.
MAP-4665: XSD: Imported transport map and listener map definitions from an older runtime into a newer runtime are not namespace aware unless XSD is re-queried
Description: If you are importing a transport map or listener map that was defined with XSDs and was created in a 12.4 or prior release, then the map needs to queried again and saved in order for 'nil' element processing to be handled correctly.
MAP-4666: Listener doesn't support XSDs with namespaces
Description: A Listener configured to process XSD based payloads will not be able to successfully handle an XML with namespace qualified elements.
Workaround: The workaround is to provide an XML request without namespaces.
Transaction Server Web Services SOAP
MAP-5181: SOAP Header Parameter limited support
Description: SOAP Header Parameter support is not available on the Enterprise Gateway for Siemens ERPC and Mitsubishi MESInterface-IT products.
TR-50
MAP-7007: TR50: Deadlock
Description: Gateway may experience a rarely occurring deadlock condition after several days or weeks of operation. If this occurs, a watchdog will expire and reset the gateway to resume operations.
MAP-8236: Wait action is not being rescheduled after a time_sync.
Description: There is known issue relating to WAIT action completing immediately when the timesync is enabled on a TR50 connection that has a drift of 2 seconds or greater. This implied that the trigger's sequence of events that are time sensitive may execute quicker than expected when the OS system time is adjusted to sync with the IoT Portal platforms' time.
MAP-10092: Option CloudGate V1 failed when running TR50 S&F disk storage type tests with error storage->create_storage failed [-33533]
Description: TR50 Store and Forward disk storage type is not supported on Option CloudGate V1 gateways.
Drivers
SRE-4996 and MAP-14482 - Remove all Azure Drivers from 19.1.10
Description: Issues found in Azure driver and is removed from the 19.1.10 release.
MAP-3140: Siemens S7 listener gets stuck in stopping state on Enterprise Gateway for Siemens ERPC
Description: After the Siemens S7 listener device receives data and a corresponding trigger is executed, stopping the Siemens S7 listener device results in the listener becoming stuck in the Stopping state. This happens during operations when the Siemens S7 listener device is using the normal TCP mode (not ISO-n-TCP). After a trigger executes the receipt of an unsolicited message, the S7 listener device cannot be stopped.
A firmware upgrade from Siemens is anticipated in order to resolve this behavior.
MAP-5066: CloudLINK package remove isn't removing the feature and MAP-5158 Package remove failed - OS error
Description: On some platforms with limited operating system resources for memory or disk (persistence storage), there may be failure when attempting to add or remove packages. These failures are the result of the limited system resources and possible runtime behavior such as memory fragmentation. When these failures occur, restarting the node at the operating system level (power off then power on) may then allow the package add or remove to succeed. In other scenarios, you may have reached a platform limit based on the application definitions, the number and size of packages added and other dynamic runtime requirements.
MAP-6082: Writing an empty string for Siemens STRINGs of length 207 or more does not clear bytes as expected
Description: If an empty string is written to a Siemens PLC, all the bytes of the string are set to 0x00 and the actual length byte is set to 0. This behavior changes when the maximum length of the string is 207 to 254 bytes. In this case the actual string length byte is set to 0, but the string bytes are not cleared. Not clearing the bytes is done to reduce the network traffic between the driver and the PLCs. Strings that are greater than 206 bytes requires the driver to send multiple messages to the server. The key to writing an empty string is setting the actual length byte to 0, so the string will have a NULL value.
MAP-6811: Siemens LOGO PLC device disables periodically
Description: Lab tests have demonstrated that the Siemens LOGO PLC will not maintain simultaneous socket connections from multiple nodes. The LOGO PLC will terminate connections, which results in the associated device becoming disabled. The disabled device will re-establish a socket connection to the LOGO, only to have that connection eventually reset by the LOGO. It is recommended that connections to the LOGO PLC be limited to one node at a time.
MAP-6938: Rockwell CIP Event will not work when Size of One Element is set to 0 and STRINGs have more than 444 characters
Description: The Rockwell CIP Event allows the Size of One Element field to be set to 0 and any messages using STRINGs of 444 characters or less to be received. However, any STRING with greater than 444 characters will result in an error. The workaround is to make sure you indicate the size of the String being read in the Size of One Element field.
MAP-7694: Subscription on device that becomes stopped generates read errors
Description: When subscribing to a started device that is later stopped, the subscription still attempts to read from that device and generates errors.
Workaround: Workbench can workaround this by stopping subs on stopped devices and restarting again on start, but keeping the subs live when the device is stopped results in fewer commands being sent.
MAP-9022: Cannot read variable when its name exceeds 128 characters on OPC UA Client
Description: A variable's location name can be a maximum of 128 characters long. The variable location name consists of the parent structure names plus the variable name. Renaming a variable to fit the 128 character limit will allow you to read and write to the variable. A variable with a location name greater than 128 characters long will not be able to be accessed, and will return an "Error: Variable does not exist" error. This page has more information: Accessing device variables.
MAP-9303: OPC UA Client driver increases core handles and memory usage during StartStopStress test (Linux)
Description: Attempting to start and stop many OPC UA clients on Linux causes the node to crash.
Workaround: Limit the number of OPC UA devices per deviceWISE node to five.
MAP-9176: OPC UA Client driver increases core handles and memory usage during StartStopStress test (Windows)
Description: Attempting to start and stop many OPC UA clients will result in leaked memory. For reference, starting and stopping 15 clients constantly for 3 hours results in ~15MB lost. Restarting a node will clear this leaked memory.
MAP-9968: BACNet Version 1.2.0 does not support Linux x64 platforms
Description: BACnet is not supported on 64-bit Linux platforms.
MAP-10011: Node crashes when disconnecting Ethernet cable when trigger is reading BACnet device variables
Description: A problem has been seen in the lab where the system restarts if the network connection to the BACnet device is lost during the device start process
MAP-10145: OPC-DA Client cannot write UINT4 value 2147483648 and greater
Description: The largest unsigned integer value that the OPC-DA Client can write is 2147483647.
MAP-12201: Atlas Copco Trace Data trigger fires even though a tightening wasn’t performed.
Description: Testing in the lab has found instances where a Trace Data (MID0900) message is being sent by the Atlas Controller to deviceWISE, even though a rundown hasn’t occurred. This causes a started Atlas Copco Trace Data trigger to fire, if it is associated with that controller. The Trigger’s Result Data Identifier Event variable can be used to determine if this is a duplicate Trace Data message.
MAP-12442: OPC UA Client driver does not run on NetComm, CalAmp LMU5000 RevC, and Lanner
Description: The OPC-UA Client driver is not supported on all platforms. Refer to the OPC-UA Client driver documentation at Supported OPC-UA Client environments.
MAP-12780: Rockwell MicroLogix 1100 and 1400 devices get stuck in Stopping state on Siemens ERPC
Description: After several variable reads and writes, stopping the device might result in the device being stuck in the Stopping state, then resetting after about 10 minutes.
MAP-13702: OPC UA Client Certificate Security does not work on VxWorks-based platforms.
Description: OPC UA Client Certificate Security feature is not enabled for VxWorks-based platforms.
MAP-13859: FANUC CNC Driver Macros floating point value write -12.3456 results in -12.3455999
Description: There is a limitation when representing floating point numbers because of Int4 precision. The max Int4 value is 2147483647, and this limits precision.
MAP-13860: FANUC CNC Driver random write failures to Macros at 500 and 98000 range on NCGuide device
Description: This is an intermittent problem with the NCGuide simulator software.
MAP-14146: FANUC CNC driver reading and writing wrong Tool Offset type
Description: We found that the Tool offset type would not write to the correct offset depending on the range provided. We removed the Tool Offset feature in 19.1.7 and plan to correct the implementation in a future release.
MAP-14436: OPC UA client and OPC UA Server do not coexist on the same node
We do not support running the deviceWISE OPC UA Server on the same node as the deviceWISE OPC UA Client.

Backup before upgrading! You should do a Backing up and Restoring a node's configuration of your configuration from the Workbench prior to upgrading to a new version of deviceWISE.
Updating from an earlier release level of an Enterprise Gateway to 19.1.12
For Windows Enterprise Gateway products:
Upgrading a Windows Enterprise Gateway product from a version before 19.1.6 to 19.1.12
We moved to a new installation architecture for Windows Asset Gateway and Enterprise Gateway products with version 19.1.6. These Special Notes apply to a one-time transition from a Windows Gateway version before 19.1.6 to a Windows Gateway version after 19.1.6:
If you are upgrading a Gateway for Windows product to version 19.1.6 or later, you must do the following:
- Perform a node backup of deviceWISE
- Backup all files used in the Staging Browser folders or properties files that were added outside of the original deviceWISE installation. (For example: C:\deviceWISE\Runtime\staging and C:\deviceWISE\Runtime\dwcore)
- Uninstall the (pre-19.1.6) version of the Enterprise Gateway for Windows product
- Install deviceWISE Enterprise Gateway for Windows or deviceWISE Asset Gateway for Windows using the given installers.
- Copy the files backed up from step #2 contained in the Staging Browser folders or properties files to the new installation folder. (For example: C:\Program Files (x86)\deviceWISE\Gateway\staging and C:\Program Files (x86)\deviceWISE\Gateway\dwcore)
- Restart deviceWISE
- Restore your node.
- After updating to 19.1.12, you will need to add all device drivers and extensions from the new 19.1.12 release level.
Upgrading a Windows Enterprise Gateway product from 19.1.6 or later to 19.1.12
If you are updating an Enterprise Gateway for Windows from the 19.1.6 release or later, then you can use the firmware update option. A firmware update from a release for Enterprise Gateway for Windows before version 19.1.6 to 19.1.12 is not supported. You must do a complete product installation as noted in the previous section.
After updating to 19.1.12, you will need to add all device drivers and extensions from the new 19.1.12 release level.
For AIX, Linux, VxWorks, or WinCPU Enterprise Gateway products:
If you are updating an Enterprise Gateway from a 17.2.3 through 19.1.11 (inclusive) release, then you can use the firmware update option. A firmware update from a release before 17.2.3 is not supported.
If you are updating an Enterprise Gateway from a 17.1.14 or earlier release to 19.1.12, you must do a complete product installation. This is required to install the supporting libraries and 3rd party support files. These supporting files are not included in a firmware update for an Enterprise Gateway, however they are included in a complete install.
After updating to 19.1.12, you will need to add all device drivers and extensions from the new 19.1.12 release level.
A firmware update from 16.1.8 or earlier to 19.1.12 is not supported for CentOS 7 or systemd installations. A full installation is required.
Updating from an earlier release of an Asset Gateway to 19.1.12
For Windows Asset Gateway products:
Upgrading a Windows Asset Gateway product from a version before 19.1.6 to 19.1.12
We moved to a new installation architecture for Windows Asset Gateway and Asset Gateway products with version 19.1.6. These Special Notes apply to a one-time transition from a Windows Gateway version before 19.1.6 to a Windows Gateway version after 19.1.6:
If you are upgrading a Gateway for Windows product to version 19.1.6 or later, you must do the following:
- Perform a node backup of deviceWISE
- Backup all files used in the Staging Browser folders or properties files that were added outside of the original deviceWISE installation. (For example: C:\deviceWISE\Runtime\staging and C:\deviceWISE\Runtime\dwcore)
- Uninstall the (pre-19.1.6) version of the Asset Gateway for Windows product
- Install deviceWISE Enterprise Gateway for Windows or deviceWISE Asset Gateway for Windows using the given installers.
- Copy the files backed up from step #2 contained in the Staging Browser folders or properties files to the new installation folder. (For example: C:\Program Files (x86)\deviceWISE\Gateway\staging and C:\Program Files (x86)\deviceWISE\Gateway\dwcore)
- Restart deviceWISE
- Restore your node.
- After updating to 19.1.12, you will need to add all device drivers and extensions from the new 19.1.12 release level.
Upgrading a Windows Asset Gateway product from 19.1.6 or later to 19.1.12
If you are updating an Asset Gateway for Windows from the 19.1.6 release or later, then you can use the firmware update option. A firmware update from a release for Asset Gateway for Windows before version 19.1.6 is not supported. You must do a complete product installation as noted in the previous section.
After updating to 19.1.12, you will need to add all device drivers and extensions from the new 19.1.12 release level.
For AIX, Linux, VxWorks, or WinCPU Asset Gateway products:
If you are updating an Asset Gateway from a 17.2.3 through 19.1.11 (inclusive) release, then you can use the firmware update option. A firmware update from a release before 17.2.3 is not supported.
If you are updating an Asset Gateway from a 17.1.14 or earlier release to 19.1.12, you must do a complete product installation. This is required to install the supporting libraries and 3rd party support files. These supporting files are not included in a firmware update for an Asset Gateway, however they are included in a complete install.
After updating to 19.1.12, you will need to add all device drivers and extensions from the new 19.1.12 release level.
A firmware update from 16.1.8 or earlier to 19.1.12 is not supported for CentOS 7 or systemd installations. A full installation is required.
For more information about upgrading your software, see Updating products.