Set TR50 Configuration

The Set TR50 Configuration action sets the TR50 Server Address , Application Token, and Custom ID parameters that are available from the TR50 feature's TR50 Connection Management tab.

Input tab

Input Description
Connection Name The TR50 connection name of the connection to perform this action on.

 (Optional) If not specified, the name of the connection used is Default.

Registration Server The TR50 Server Address parameter.
This parameter can also be set using the TR50 feature's TR50 Connection Management tab.
An example value for this parameter is: api.devicewise.com.

(Optional) If not specified, the current value for the Registration Server is not changed.

App Token The TR50 Application Token parameter. For more information on Applications and Application Tokens, see Applications.

(Optional) If not specified, the current value for the App Token is not changed.

Custom ID A custom Thing Key. The valid characters for a Custom ID are: letters, numbers, "_" (underscore) , and "-" (hyphen).

(Optional) If not specified, the current value for the Thing Key is not changed.

The TR50 connection Status must be a value other than Connected for the Set TR50 Configuration action to succeed. For more information, see Control TR50 Connection.
After setting the TR50 Configuration parameters, the TR50 connection State must be changed to Started to establish a TR50 connection to the deviceWISE Cloud.

Related topics

Applications

Control TR50 Connection

TR50 Connection Management tab